SYSTEM RATING |
WIDTH |
HEIGHT |
SQ. IN. |
MAXIMUM STOP HEIGHT |
TYPE |
| Pyrobel-45-16 |
45 min |
96" |
96" |
4608" |
1" |
Borrowed lite |
| Pyrobel-60-25 |
60 min |
94 1/2" |
94 1/2" |
4487" |
1" |
Wall system |
| Pyrobel-90-37 |
90 min |
82 3/8" |
82 3/8" |
3418 1/2" |
1" |
Borrowed lite |
| Pyrobel-120-52 |
120 min |
88" |
88" |
3828" |
1" |
Wall system |
Maximum Wall Size
The maximum wall size is unlimited subject to an engineers review of
structural components.
Glazing
Consult individual data sheets for above mentioned products for glazing
limitations and restrictions.
Listing
Testing completed by Intertek Testing Services Warnock-Hersey
Certification in accordance with ASTM-E119, CAN 4S-101, NFPA-251,
UL-263, UBC 7-1 (1997) and IBC 7-1.
Recommendation
Some Authorities Having Jurisdiction may be unfamiliar with the
"transparent wall system" concept. It is suggested that this system be
reviewed and approved prior to commencing activities.
 |